Alpha Technologies Inc.
Phone: 360 647 2360
Email: alpha@alpha.com
CSM02
CSM02 Modular DC to DC Converter
  • Available in 20, 30, 50 and 60A system capacities
  • Accommodates up to six, 10A power modules per system
  • Offers hot plug-in operation
  • Isolated input and output
  • Optional extended temperature range
  • Optional supervisory control module


The CSM02 is a compact, modular DC-DC converter system designed for communications applications. The CSM02 DC-DC converter utilizes Argus’ advanced switched-mode technology to provide outstanding efficiency in a compact design. Available in either a horizontal or vertical cabinet configuration, the CSM02 achieves power conversion efficiencies greater than 85 percent at full load, resulting in significant energy savings over competitive units.

The CSM02 incorporates a comprehensive range of standard and optional features allowing it to fulfill an extensive list of applications. Standard features include input/output termination’s, current limit, over voltage protection, test points, over temperature protection and fuses. Options include low temperature operation, low/high voltage alarm, adjustable OVP, fuse distribution, input breaker, on board microprocessor for remote monitoring, and a serial communications interface.
CSM02 Modular DC to DC Converter
Power Module (s)
Electrical
Input voltage:40 to 60 Vdc
Output voltage:22 to 26 Vdc
Output current:10A
Efficiency:>85% (100% load)
Regulation:-1%, +/-0.1% load (static)
+/-0.1% line (static)
<2% deviation for 50 to 100% load step (dynamic)
Response Time:2 ms to 0.1% of output for 50 to 100% load step
Noise:
Voice band:<22 dBrnC
Wide band:<10mV RMS (10kHz to 10MHz)
<150mV pk to pk (10kHz to 100MHz)
Acoustic:45 dBa at 1m (3 ft)
Features
Indicators:Power on
Output over voltage protection trip
Bar graph output current
Converter fail
Current limit
Alarms:Converter fail alarm†
Adjustments:Output voltage
Protection:Input fuse
Input inrush current limiting
Over temperature limiting
Input high and low voltage shutdown
Output paralleling diode
Current limit/short circuit protection
Environmental Specifications
Temperature:0° to 50°C (32° to 122°F) with specified ventilation
-40° to 50°C (-40° to 122°F) (optional)
Humidity:0 to 95% R.H. non-condensing
Elevation:-500 to 2800m (-1640 to 9186 ft)
Analog Supervisory Module
Features
Indicators:Major alarm
System over voltage protection trip
System high voltage alarm
System low voltage alarm
Test mode
Digital voltmeter/ammeter
Alarms:Major alarm†
Low voltage alarm†
High voltage alarm†
Adjustments:Over voltage protection
High voltage alarm
Low voltage alarm
Test/normal selector
Shelves
Mechanical
Connections:
Input/output:Two 1/4” studs on 5/8” centers
Alarm/control:Terminal block
0.5 mm2 to 1.5 mm2 (#20 to 16AWG)
20A30A50A60A
Weight:8.4 kg (18.5 lb.) e/w10.9 kg (24 lb.) e/w16.6 kg (36 lb.) e/w19.5 kg (43 lb.) e/w
2 power modules3 power modules5 power modules6 power modules
Dimensions
mm90 H x 432 W x 305 D90 H x 508 W x 305 D178 H x 432 W x 305 D178 H x 508 W x 305 D
inches3.5”H x 17”W x 12”D3.5”H x 20”W x 12”D7”H x 17”W x 12”D7”H x 20”W x 12”D
Input Module
Features
Indicators:Circuit breaker trip
Alarms:Circuit breaker trip alarm
Distribution Fuse Module
Features
Indicators:Output fuse fail
Alarms:Output fuse alarm†
Fuse block:8 position 0 to 10A GMT fuses
(50 and 60A versions)
4 position 0 to 10A GMT fuses (20A version)
Connections:Terminal block
0.75 mm2 to 4 mm2 (#18 to #12 AWG)
Document Downloads
Title Type Version Date
CSM02 48V to 24V Datasheet_Eng (LTR) Datasheet 048-523-10 May 1, 2004