Alpha XM2-HP and XM2 embedded status monitoring
Standard network interface including SNMP, Web access and ANSI/SCTE HMS MIBs
Monitors one or two 36V or 48V battery strings
Used with EDSM interface card
Optional VoIP testing features
Alpha’s XMS2 Digital Embedded DOCSIS® Transponder model IDH3 enables cable operators to manage their network powering through the existing cable modem infrastructure. Multiple power supplies, batteries and a generator can be monitored using a single transponder. Data is transmitted to a management system over the network’s DOCSIS cable modem channels through the existing CMTS. Bandwidth utilization is minimized by using standard SNMP (Simple Network Management Protocol) communications. Status monitoring information is compatible with ANSI/SCTE HMS standards.
The IDH3 can also be optionally enabled as an E-MTA to perform an advanced suite of IP and VoIP tests, thus turning it into a true cross-domain test point by combining measurements available from the HFC, DOCSIS, IP and VoIP domains.
The
SCTE-HMS Management Information Base (MIB)
can be monitored with a SNMP compatible Network Management System (NMS) or with a MIB browser. MIB files are required for the MIB browser to collect data from the transponder.
AlphaNet IDH3
General Specifications
Power Supplies Supported:
XM2-HP, XM2
Battery Monitoring:
Up to two strings of 36V or 48V batteries
Monitoring Protocol:
SNMP v1
Devices Monitored:
Power Supply, Batteries and AlphaGen (compatible with ANSI/SCTE 25-3 2002, formerly HMS 022)
Management Protocol:
Standard ANSI/SCTE HMS MIBs support basic power supply monitoring
Hardware Specifications
RF Cable Interface:
F-connector, female, 75Ohm
Local Interface:
RJ-12, RS-232, 19.2kb,N,8,1
Requires serial port adapter and PC with terminal emulation software (Hyper-Terminal recommended)
LED Indicators:
Transponder Ready/RF Link Established
Transponder/CMTS Communications
Power Supply/Transponder Communication
I/O Signals:
Battery, tamper, and AlphaBus interfaces located on EDSM interface card
Environment
Operating Temperature:
-40 to 65°C / -40 to 149°F
Storage Temperature:
-40 to 85°C / -40 to 185°F
Humidity:
10 to 90% non-condensing
Emissions:
EN50022 Class A and FCC Part 15 Class A (Installed in power supply enclosure system)
Cable Modem
Compliance:
DOCSIS 1.1 and 2.0
Transmit Frequency Range:
5 to 42 Mhz
Receive Center Frequency Range:
91 to 857 Mhz
Output Power Range:
8 to 58 dBmV
Input Signal Range:
-15 dBmV to 15 dBmV
Channel Bandwidth:
6 Mhz
Power Supply Monitored Parameters
Major Alarm:
Aggregate Alarm consisting of: test fail, battery fail, line isolation alarm, output overload, inverter over temperature, N+1 active, fuse fail
Minor Alarm:
Aggregate Alarm consisting of: temperature probe error, AC line loss, N+1 error
Input Line Voltage:
Reported from power supply V(in) measurement
Output Voltage:
Reported from power supply V(out) measurement
Output Current 1-4:
0-25A standard on port 1. Ports 2-4 require power supply option.
Output Power:
Calculated, reported in AC Watts
UPS Status:
AC line, Standby, Test in-process, Test alarm
Enclosure Door:
Open/Closed
Battery Voltage:
Up to 2 battery strings
Individual battery voltages measured reported to ±100mv resolution
Battery Temperature:
Reported from power supply battery Remote Temperature Sensor (RTS)
Remote Test Control:
Start/Stop XM2 self test cycle
Generator Monitored Parameters
Status:
Generator off, running, alarm
Generator Alarm:
Aggregate alarm consisting of: low oil pressure, engine over-temp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail
Gas Hazard:
OK, Alarm
Water Intrusion:
OK, Alarm
Pad Shear:
OK, Alarm
Enclosure Door:
Open, Alarm
Ignition Battery Voltage:
+/- 100mV
Enclosure Temperature:
+/- 2°C
Low Fuel:
OK, Alarm
Remote Test:
Start and Stop control input
Document Downloads
Title
Type
Version
Date
AlphaNet IDH3 Datasheet_Eng
Datasheet
049-299-10-A001
June 17, 2009
AlphaNet IDH3 Technical Manual
Manual
745-420-B0-001 Rev. A
January 30, 2010
EDSM Technical Manual
Manual
704-721-C0-004 Rev. D
May 1, 2008
Total Power Solutions™
Home
Products
About Alpha
News Room
Document Downloads
Contacts
Careers
Legal
Need Some Help?
Sitemap
Copyright © 2008 - 2012, The Alpha Group. All Rights Reserved.