Technical Specifications| Power Supply Monitored Parameters |
|---|
| Major Alarm: | Aggregate alarm consisting of: test fail, battery fail, line isolation alarm, output overload, inverter over temperature, N+1 active, fuse fail |
|---|
| Minor Alarm: | Aggregate alarm consisting of: temperature probe error, AC line loss, N+1 error |
|---|
| Input Line Voltage: | 90-270Vac 50/60Hz measured value |
|---|
| Output Voltage: | 60/75/90Vac measured value |
|---|
| Output Current 1: | 0 to 25A measured value |
|---|
| Output Current 2,3,4: | 0 to 25A measured value (if optional ports installed) |
|---|
| Output Power: | Calculated, reported in AC Watts |
|---|
| UPS Status: | AC line, Standby, Test in-process, Test Alarm |
|---|
| Enclosure Door: | Open/Closed |
|---|
| Battery Voltage: | 6V or 12V batteries, up to 16 batteries |
|---|
| Individual battery voltages measured reported to ±100mv resolution |
|---|
| Battery Temperature: | Measured, reported in Celsius |
|---|
| Remote Test Control: | Start/Stop XM2 self test cycle |
|---|
| Generator Parameters |
|---|
| Status: | Engine off, running, alarm |
|---|
| Generator Alarm: | Aggregate alarm consisting of: low oil pressure, engine over-temp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail |
|---|
| Gas Hazard: | OK, Alarm |
|---|
| Water Intrusion: | OK, Alarm |
|---|
| Pad Shear: | OK, Alarm |
|---|
| Enclosure Door: | Open, Closed |
|---|
| Ignition Battery Voltage: | 10.2 – 15.5Vdc, 100mV resolution |
|---|
| Enclosure Temperature: | -40 to 100°C (-40 to 212°F) |
|---|
| Low Fuel: | OK, Alarm |
|---|
| Remote Test: | Start and Stop control input |
|---|
| DOCSIS Network |
|---|
| Compliance: | DOCSIS 2.0 (EuroDOCSIS 2.0) |
|---|
| Upstream Frequency: | Range 5 to 42 MHz (5 to 65 MHz EuroDOCSIS) |
|---|
| Downstream Center Frequency Range: | 91 to 857 MHz (108 to 862 MHz EuroDOCSIS) |
|---|
| Channel Bandwidth: | 6 MHz (8 MHz EuroDOCSIS) |
|---|
| Receive Power Level: | -15 to 15 dBmV |
|---|
| Transmit Power Level: | 8 to 58 dBmV |
|---|
| Management |
|---|
| Standard Network Protocols: | IP, TFTP, DHCP, UDP, HTTP, SNMPv1, v2c Web interface provides access to common cable modem and power system data with secure access to configurable parameters. |
|---|
| SNMP MIBs: | ANSI/SCTE 38-4 2006 HFC Outside Plant Power Supply Status Monitoring MIB |
|---|
| ANSI/SCTE 38-6 2006 HFC Outside Plant Generator Monitoring MIB |
|---|
| ANSI/SCTE 38-2 2005 HFC Outside Plant Alarms MIB |
|---|
| ANSI/SCTE 38-1 2004 HFC Outside Plant Property MIB |
|---|
| ANSI/SCTE 38-3 2002 HFC Outside Plant Common MIB |
|---|
| ANSI/SCTE 37 2003 HFC Outside plant HMS Roots MIB |
|---|
| ANSI/SCTE 36 2002 SCTE Root MIB |
|---|
| Alpha Proprietary Broadband Management MIB |
|---|
| Alpha Approved 3rd Party Management Systems : | CheetahXD - Tollgrade Communications |
|---|
| Continuity - Seldon Systems |
|---|
| iGlass - iGlass |
|---|
| Net Informer - Cableware |
|---|
| Netcool - IBM |
|---|
| Omni & BOSS - AM Networks |
|---|
| Power Sense - Auspice |
|---|
| ROSA - Scientific Atlanta |
|---|
| Spectrum - Computer Associates |
|---|
| (Other SNMP compatible management systems integrating HMS MIBs) |
|---|
| User Interface |
|---|
| Power Supply Front Panel Display: | Additional parameters shown on XM2 display with DSM2 installed: |
|---|
| Individual battery cell voltage |
|---|
| Cable modem MAC address (plus CPE MAC address in dual-IP mode) |
|---|
| Cable modem IP address (plus CPE IP address in dual-IP mode) |
|---|
| Cable modem receive power level |
|---|
| Cable modem transmit power level |
|---|
| Cable modem & DSM2 firmware version |
|---|
| LED Indicators Craft Port: | Alarm, Ready, Comm, Link, Downstream, Register RS-232 local access to power supply, battery, generator and network parameters. Detailed status and diagnostic information. |
|---|
| Full configuration access |
|---|
| Communication Parameters: 19,200 baud, no parity, 8 data bits, 1 stop bit |
|---|
| Hardware / Environmental Specifications |
|---|
| Power Supplies Supported: | Alpha XM2, XM2VP, GMX, VMX Series |
|---|
| RF interface: | Female F-connector, 75 Ohm |
|---|
| Tamper: | 2-pin connector |
|---|
| Battery inputs A/B: | Battery strings A and B, 36V or 48V, 8 pin, female, keyed mate and lock |
|---|
| Combination A+B configurable for 6V batteries using 6 x 6V = 36V string |
|---|
| Battery inputs C/D: | Battery strings C and D, 36V or 48V, 8 pin, female, keyed mate and lock |
|---|
| Multiple XM2 and Generator interface: | RJ-12 Offset connector supports RS-485 multi-drop interface for up to 5 XM2 power supplies and an AlphaGen generator. |
|---|
| SI interface card required for additional XM2 modules. ECM interface required for AlphaGen. |
|---|
| Operating Temperature: | -40 to 65°C (-40 to 149°F) |
|---|
| Storage Temperature: | -40 to 85°C (-40 to 185°F) |
|---|
| Humidity: | 10 to 90% non-condensing |
|---|
| Emissions: | EN50022 Class A; FCC Part 15, Class A (installed in power supply system) |
|---|
| Warranty: | Two (2) years when installed with approved grounded surge arrestor. |
|---|