Alpha Technologies Inc.
Phone: 360 647 2360
Email: alpha@alpha.com
AlphaNet EDH-A2
AlphaNet™ EDH-A2
  • Adds DOCSIS Status Monitoring capability to existing power supplies
  • DOCSIS certified, uses existing head-end equipment
  • Compatible with ANSI/SCTE HMS standards
  • Power supply support includes: XM, AM, XM2, ZTT series
  • Embedded Web server for remote diagnostics
  • Local port interface


Alpha’s external DOCSIS transponder provides the ability for cable operators to manage network powering through the existing cable modem infrastructure. DOCSIS certifi cation, SNMP and HMS MIB support, and an embedded web server enable the XP-EDH-A to provide power network data quickly and easily when and where it is needed. The transponder is fully interoperable with multiple power supply models and can be accessed using any SNMP Manager.

The SCTE-HMS Management Information Base (MIB) can be monitored with a SNMP compatible Network Management System (NMS) or with a MIB browser. MIB files are required for the MIB browser to collect data from the transponder.
AlphaNet EDH-A2
General Specifications
General
Model:XP-EDH-A2
Power Supplies Supported:XM2-HP
XM2 (requires USM2 or USM2.5)
XM (requires APM/USM)
Lectro ZTT, ZTT+ and CPR
AM (requires RPM card)
DOCSIS Compatibility:DOCSIS 1.1, 2.0
Monitoring Protocol:SNMPv1
Devices Monitored:Power Supply, Batteries
RF Transmit/Receive
Tx Frequency Range:5 to 42MHz
Output Power:8 to 55dBmV
Channel Bandwidth:6MHz
Receive Center Freq Range:91 to 857MHz (Standard, HRC, IRC channels)
Input Level:-15 to 15dBmV
Monitored Parameters
Power Supply Data
Model:XM2XMAMZTT Series
Major Alarm:XXXX
Minor Alarm:XXXX
Input Line Voltage:XXXX
Output Voltage:XXXX
Battery Voltage:XXXX
Output Current:XXXX
Standby/AC Line Fail:XXXX
Equipment/Test Fail:XXX
Enclosure Door Status:XXXX
Remote Test Control:XXXX
Number of Battery Strings:Up to two 36V or 48V strings
Battery Data:Individual Battery Voltages
Battery Compartment Temperature
Hardware
Dimensions H x W x D (in/mm):1.3 x 8.6 x 5.2 / 33 x 218 x 132
RF Cable Interface:F-connector, female, 75Ohm
Local Port Interface:USB
Environment:-40°F to 149°F (-40 to 65°C)
10 to 90% non-condensing humidity
Emissions:EN55022 Class A and FCC Part 15 Class A (Installed in power supply enclosure system)
Immunity:Surge Test per Specification (IEEE C62.41-1991)
ESD Protection: ±8kV air discharge, ±8kV contact discharge as per (IEC 61000-4-2)
Management
NMS/EMS:Standard SNMP Management Tools
HMS MIBs:
In addition to the standard DOCSIS MIBs, the transponder supports the following HMS MIBs:
SCTE 25-3 (HMS-022):Interface
SCTE 36 (HMS-050):Root
MIB SCTE 37 (HMS-072):Tree
MIB SCTE 38-1 (HMS-026):Property
MIB SCTE 38-2 (HMS-023):Alarm MIB
SCTE 38-3 (HMS-024):Common
MIB SCTE 38-4 (HMS-027):Power Supply
MIB SCTE 38-7 (HMS-050):TIB MIB
Document Downloads
Title Type Version Date
AlphaNet EDH-A2 Datasheet_Eng Datasheet 049-289-10-A001 November 1, 2008
AlphaNet™ Series Technical Manual_Eng Manual 745-838-B2-001 Rev. A March 23, 2010
Alpha XP-EDH-A2 Transponder Field Installation Instructions Manual 745-838-C5-001A July 22, 2009