Alpha Technologies Inc.
Phone: 360 647 2360
Email: alpha@alpha.com
Broadband Ferro Series
  • Ferro design provides maintenance free network power protection
  • Flexible mounting arrangements to meet various installation needs
  • Rugged construction for long life


The Lectro Ferro Series employs a simple, compact design that regulates voltage and protects against surges and spikes without complex electronics. Lectro Ferros are the perfect choice for non-standby applications where battery back-up is not required. All Lectro Ferros feature foldback protection for overload conditions and automatic recovery. An advanced heatsink design dissipates heat quickly to ensure long transformer life. Each Lectro Ferro model is available in either a pole or ground mount configuration and is deployable in a variety of applications.
Broadband Ferro Series
Nominal Specifications
Model:BroadbandMini-MaxMini-Mite
Electrical
AC Input Voltage Range:120Vrms120Vrms120Vrms
AC Input Voltage Regulation:20%20%20%
AC Output Frequency Range:60Hz60Hz60Hz
AC Output Voltage:60 or 87Vrms60Vrms60Vrms
AC Output Voltage Regulation:±3%±3%±3%
Efficiency @ Full Load:90%88%80%
Output Configurations:9A, 12A, 15A6A, 9A, 12A, 15A2A4A
Mechanical
Pole Mount12A/15A12A/15A2A4A
Height (in/mm):15/38115.2/3868.25/2108.25/210
Width (in/mm):9.25/2357.25/1976.19/1586.19/158
Depth (in/mm):8.38/2138.38/2134/1024/102
Weight (lb/kg):56/22.534/1510/4.513/5.9
Ground Mount12A/15A12A/15A
Height (in/mm):22/55922.2/561
Width (in/mm):9.25/2357.25/197
Depth (in/mm):8.38/2136.87/175
Weight (lb/kg):56/22.534/15
Overload Protection
Ferroresonant OutputFoldback Limited @ 150% of output rating
Environmental
Operating Range-40 to 55°C (-40 to 131°F)
AC Input Voltage Regulation-40 to 55°C (-40 to 131°F)
Humidity5 to 95% non-condensing
Document Downloads
Title Type Version Date
MiniMax Power Supply Installation and Operation Manual Manual 164201241-001 Rev. C0 November 1, 2003
Mini-Mite Ferro Power Supply 30/60VAC Output Operator’s Manual Manual CM003101 June 1, 2006