FlexPoint AX Series
FlexPoint™ AX Series
  • Scalable FTTP/FTTx power supply systems with and without standby
  • Full or partial outdoor configurations
  • Outdoor rated including battery for 24/7 availability
  • Utility meter base provides most reliable source of AC power at home
  • No homeowner appointments needed for access
  • Safe, Limited Power Source (LPS) distribution
  • 30W with battery module, 24W without battery module


Alpha’s FlexPoint AX Series fiber to the premises optical network terminal (ONT) power supply system, provides network operators a highly reliable, scalable set of solutions for full or partial outdoor installations. Service technicians have 24/7 access to the power system, eliminating the need to coordinate maintenance house calls with the subscriber. FlexPoint AX home converters and power ring converters provide 12Vdc support for indoor and outdoor applications not requiring standby power. As voice or critical data services expand, 7.2 or 17AH battery back up power supplies (BBPS) can be easily added. Battery management modules are available for integration in optical network terminal enclosures reducing the number of enclosures located at the subscribers home.
FlexPoint AX Series
Input Specifications
AC Input Voltage (AX30-12D-HC)85 to 132Vac (120VAC Nominal)
AC Input Voltage (AX-30-12D-PC)170 to 264Vac (230VAC Nominal)
AC Input Frequency50 to 60Hz
Note International AC selections and line cords available.
Output Specifications
DC Output Voltage
PC/HC + BBPS (UPS System)10.5 to 14.4Vdc
PC/HC (Non UPS)11.6Vdc
Continuous Output Power
PC/HC + BBPS (UPS System)30W at nominal battery float voltage
PC/HC (Non UPS)24W/35W
Max. Output Power (UPS System)(<10s) 45W
Max. Output Power (Non UPS)2.4A current limit (HC/PC)
Short Circuit ProtectionElectronic
DC Ripple150mV
Environmental Specifications
Operating Temperature Range
AX-30-12D-PC + BBPS:-40° to 55°C / -40° to 131°F
AX1235LPS-HC + BBPS:HC: -40° to 45°C / -40° to 113°F,
BBPS: -40° to 63°C / -40° to 145°F
AX1235LPS-HC:-40° to 45°C / -40° to 113°F
Humidity:0 to 95% humidity
Elevation Operation Max.:3000m / 10000ft
Elevation Storage Max.:15000m / 50000ft
Battery Specifications
Type:Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Recharge Time:AX-12D-BBPS-7.2-LPS: <16hrs with 24W load
AX-12D-BBPS-17-LPS: <36hrs with 24W load
Regulatory Approvals
Home Converter:CSA Listed System Class II LPS, FCC Part 15, Class B, EN60950-1, RoHS, CE
Power Ring:UL-Recognized Components
Power Ring Converter:UL-Recognized Components
BBPS Modules:CSA Component, Class II LPS
Warranty
Electronics:2 years
Battery–Standard:1 year
Battery–Long Life:3 years
Status Alarms
Local (LED Indicators)
Green Steady:Output OK
Green Blinking:Standby Operation
Red Steady:Replace Battery
Red Blinking:Battery Missing/Battery Low
Remote (Status Alarms – PacketCable™ Compliant)
AC Fail:Output Power drawn from battery
Replace Battery:Battery has failed periodic self-test
Battery Missing:Battery is disconnected
Battery Low:Battery has 20% remaining runtime
FlexPoint UPS Runtimes (Minutes) over Temperature
7.2AH 17AH
Load/Temp. -40°C / -40°F -20°C / -4°F 25°C / 77°F -40°C / -40°F -20°C / -4°F 25°C / 77°F
7W 360 560 800 - - -
10W 160 360 500 750 1080 1240
15W 110 195 320 400 680 940
18W 80 156 240 - - -
20W 60 130 210 60 440 6800
25W 50 100 170 160 340 480
30W 30 80 130 140 232 400
Document Downloads
Title Type Version Date
FlexPoint AX Series Datasheet_English (LTR) Datasheet 049-218-10-009 April 3, 2008
FlexPoint AX Series Datasheet_English (A4) Datasheet 049-218-11-008 March 1, 2008
FlexPoint Installation Manual Manual 010-318-C0-006 Rev. F June 1, 2006