CSM01 Modular DC to DC Converter
24Vdc to 48Vdc, 5A output
4RU vertical mount — 5 modules in 19", 6 modules in 23"
2RU horizontal mount — 2 modules in 19", 3 modules in 23"
Scalable hot plug-in operation
Convection cooled
The CSM01 is a compact, modular DC to DC converter system designed for communications applications. Using switched-mode technology, the CSM01 provides outstanding efficiency in a compact design.
The CSM01 achieves power conversion efficiencies greater than 85 percent at full load, resulting in significant energy saving over competitive units. The CSM01 packs maximum power into minimum space, but doesn’t compromise on features. A fully equipped vertical mount CSM01 system can accommodate up to six modules — a total output capacity of 30A — as well as a supervisory module, distribution module and input module. Horizontal mount provides up to 15A capacity.
Argus’ CSM modular DC to DC converter systems incorporate a full range of standard and optional features to meet the needs of a range of applications.
CSM01 Modular DC to DC Converter
Power Module (s)
Electrical
Input Voltage:
20 to 30Vdc
Output Voltage:
44 to 52Vdc
Output Current:
5A
Efficiency:
>85% (100% load)
Regulation:
-1%, ±0.1% load (static), ±0.1% line (static), <2% deviation for 50 to 100% load step (dynamic)
Response Time:
2 ms to 0.1% of output for 50 to 100% load step
Noise
Voice band:
<22dBmC
Wide band:
<10mV RMS to 10MHz
<150mVp-p to 100MHz
Psophometric:
<0.5mV
Acoustic:
<45dBa @ 1m (3ft)
Mechanical
mm:
178H x 70W x 254D
inches:
1H x 2.75W x 10D
Features
Indicators:
Power on
Output over voltage protection trip
Bar graph output current
Converter fail
Adjustments:
Output voltage
Current limit
Test points:
Module voltage
Protection:
Input fuse
Input inrush current limiting
Output paralleling diode
Over temperature limiting
Input high and low voltage shutdown
Current limit/short circuit protection
Environmental Specifications
Temperature
0 to 50°C / 32 to 122°F with specified ventilation, -40 to 50°C / -40 to 122°F (optional)
Humidity
0 to 95% RH non-condensing
Elevation
-500 to 2800m / -1640 to 9186ft
Shelves
19" shelf, 2RU
23" shelf, 2RU
19" shelf, 4RU
23" shelf, 4RU
Weight:
8.4kg (18.5lb) e/w 2 power modules
10.9kg (24lb) e/w 3 power modules
16.3kg (36lb) e/w 5 power modules
19.5kg (43lb) e/w 6 power modules
Dimensions
mm:
90H x 432W x 305D
90H x 508W x 305D
178H x 432W x 305D
178H x 508W x 305D
inches:
3.5H x 17W x 12D
3.5H x 20W x 12D
7H x 17W x 12D
7H x 20W x 12D
Connections
Input:
2-hole ¼" studs on ⅝" centers>
Output:
2-hole ¼" studs on ⅝" centers>
Alarms:
Terminal block>
0.55 to 1.5mm2 (20 to 16AWG)>
Features
Alarms:
Major alarm>
Low voltage alarm>
Shelf Components
Distribution Module Features
Indicators:
Fuse fail
Alarm:
Output fuse alarm
Fuse block:
8 position 0 GMT fuse block
(25 and 30A versions)
4 positions GMT fuse block
(10A version)
Connections:
Terminal block
0.75 to 4mm2 (18 to 12AWG)
Supervisory Module Features
Indicators:
Major alarm
System over voltage protection trip
System high voltage alarm
System low voltage
Test mode
Digital voltmeter/ammeter
Standards
EN
55022 - Class A (radiated)
FCC
Part 15 Class A (radiated)
Document Downloads
Title
Type
Version
Date
CSM01 Datasheet - English (LTR Low Res.)
Datasheet
D01
June 1, 2006
CSM01 Datasheet- English (A4 Low Res.)
Datasheet
D02
June 1, 2006
Total Power Solutions™
Home
Products
About Alpha
News Room
Document Downloads
Contacts
Careers
Legal
Need Some Help?
Sitemap
Copyright © 2008 - 2010, The Alpha Group. All Rights Reserved.