FlexNet™ FMPS
FlexNet™ FMPS
  • Fiber-to-the-Premises UPS for Multiple Dwelling, Multiple Tenant and Small Business Unit applications
  • Supports one or two MDU/SBU ONTs located up to 100ft from FMPS
  • Battery management performs periodic battery capacity testing and status reporting to the ONT and customer
  • Battery heater option provides extended runtime for applications in cold weather conditions
  • Hybrid 16AWG and alarm cable minimizes installation labor
  • Status indicators and audible alarm provide local reporting


The FTTx Multipurpose Power Supply (FMPS) is an outdoor or indoor system providing 150Watts of 48Vdc power to MDU and SOHO optical network terminals. The FlexNet FMPS is an environmentally hardened wall mount enclosure system with dual ONT connections supported with one or two 48Vdc string of 7.2AH batteries. The system includes one or two parallel outputs and alarm connections, supporting distances of up to 100ft between the FMPS and ONT, allowing the FMPS to be located close to existing power outlets.
FlexNet FMPS
Input Specifications
AC Input Voltage:90 to 320Vac
AC Input Frequency:45 to 66Hz
Surge protection:ANSI/IEEE Std. C62.41 to Category A, B, or C requirements, using a “Ring Wave” or
“Combination” waveform, at a level of 6kV
Output Specifications
Operational Output Power:150W continuous - 170W, 10sec max.
Output Voltage:48 to 58Vdc w/AC power, 42 to 58Vdc with battery
Output Current:3.1A typical (crowbar limited beyond 5A DC)
Output Power Loading:Following GR-909 telephone lines in various states, e.g., ringing, off-hook, on-hook, data, and video operation requirements.
Ripple:Less than 3mVrms
Noise:Less than 100mV pk to pk
Output Connection:Two terminal blocks accepting 16AWG, parallel connections
Local Alarms
System LED:Green Steady = System Output Normal, DC Output
Off = No AC or Battery Power
Battery LED:Yellow Steady = System on Battery
Off = Normal Mode
Replace Battery:Red Steady = Replace One or Two Battery Strings
Off = Batteries Within Parameters
Replace Battery A and B (Internal):Steady Red = Replace One or Both Battery Strings
Off = Batteries Within Parameters
Remote Alarms
Connection:Two five position IDC 24AWG, parallel connections
Pin 1 Alarm Return:Open collector return reference
Pin 2 AC Fail:On battery
Pin 3 Replace Battery:One or both battery strings failed periodic self test
Pin 4 Missing Battery:Less than eight batteries
Pin 5 Battery Low:Battery string voltage is less than 46.8Vdc
Local - Audible Indicator
Alarm On:“Alarm Enable/Disable” toggle switch located on UPS Batteries Below Voltage Parameters
Physical Specifications
FMPS
Dimensions H x W x D (in/cm):23.75 x 14 x 5.5 / 603.4 x 355.6 x 139.7
Weight(lb/kg):25 / 11.3
FMPS + Shipping Carton
Dimensions H x W x D (in/cm):28.5 x 17 x 11.75 / 723.9 x 431.8 x 298.5
Weight (lb/kg):30 / 13.6
Battery Specifications
Battery Type:Four or eight 7.2AH Valve Regulated Lead Acid (VRLA)(Batteries sold separately)
Environmental Specifications
Operating (with heater option):-40° to 46°C / -40° to 115°F plus solar loading
(without heater option):-10° to 46°C / 14° to 115°F plus solar loading, 0 to 3000m / 0 to 10,000ft elevation
Humidity:0 to 95% non-condensing
Storage:-15° to 85°C / -5° to 185°F, 0 to 15000m / 0 to 50,000ft elevation
Compliance
CSA/UL 60950, EN 60950, EN 55022 Class B, FCC Part 15 Class B, GR 63 Sect 4.2 Fire Resistance, GR-1089 Sect 3 Emissions, Sect 4 Lightning and AC Power Fault, Sect 7 Electrical Safety
Warranty
3 year repair or replace
FMPS user interface connections FMPS with cover removed and two 7.2AH battery strings installed
FMPS user interface connections FMPS with cover removed and two 7.2AH battery strings installed
Document Downloads
Title Type Version Date
FlexNet FMPS Datasheet_English (LTR) Datasheet 049-218-23-004 October 4, 2007
FlexNet FMPS Datasheet_English (A4) Datasheet 049-218-26-003 October 4, 2007
FlexNet FMPS Installation Manual Manual 010-592-B2 Rev. A September 19, 2008