Surge Protection
Surge Protection

Lightning is the primary enemy of every power network.

  • UL 1449 3rd Edition Approved
  • Critical protection from voltage transients
  • Plug-in or hardwired utilizing Metal Oxide Varistors (MOV) protection
  • SM Series Alarms when equipment is unprotected
  • VSS 120/VSS 240 Series provides downed power line protection


Alpha’s surge protection devices provide reliable protection of power supplies and related equipment from the damaging powerline disturbances common to cable and broadband applications.

LAP Plug-in Surge Protectors

    • Economic nationwide protection from damaging voltage transients
    • Unique pass through design allows the user to plug accessories in directly to the LAP not wasting any receptacle outlets
    • LED protection status indicator

COAX Protectors

    • Installs on the drop protecting the DOCSIS transponder from damaging voltage transients
    • Incorporates patented In-Line® Coaxial Gas Tube Surge Protection

ISA In-Line Surge Arrestor

    • Hard wired to service entrance to protect the power supply and accessories from damaging voltage transients
    • LED protection status indicator
    • Recommended for high density areas
Lightning Density Map
Lightning Density Map
Lightning data provided by the National Lightning Detection Network®
Operating Voltage: 120V Models 240V Models >120/240V Models
Model Selection: Good Better Best Best Best Best Good Best Best
Series Model: LA-P+120 LA-P-120T LA-P-120S LA-P-120SM VSS 120-152 VSS 120-202 LA-P+240 ISA 120/240 VSS2402
Status Monitor Harness: No No No Yes No No No No No
Protection: L/N/G L/N/G L/N/G L/N/G L/N/G L/N/G L1/L2/G L/N/G L1/L2/G
Operating Temperature: -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F -40 to 55°C / -40 to 131°F
LED Indicator: Yes Yes Yes Yes Yes Yes Yes Yes Yes
UL 1449 3rd Edition Specifications
Voltage Let Through Protection Rating: 700Vp 500Vp 600Vp 600Vp 500Vp 500Vp 1200Vp 700Vp/1200Vp 500Vp
Nominal Discharge Current Rating: 3kA 3kA 5kA 5kA 20kA 20kA 3kA 10kA 20kA
Maximum Continuous Operating Voltage (MCOV): 150Vac 130Vac 175Vac 175Vac 275Vac 275Vac 320Vac 150Vac/300Vac 275Vac
Notes:
1 The ISA surge protection devices are factory wired on the load side of the service entrance and are available for field replacement. These arrestors should be installed by a licensed electrician.
2 Pending UL 1449 3rd edition certification.
Surge Protection
Coax Protectors
Ideally suited to protect costly status-monitoring transponders, digital set top boxes, cable modems and satellite receivers in the headend as well as high-end HDTV sets from potentially damaging surges. The patented coaxial gas tube surge protector is equipped with an integral fail-safe mechanism. Listed to UL 497, CSA Listed Certified and Complies with 1999 National Electric Code.
Part NumberDescription
162-029-10:Female/Female connector configuration, “F” type connector
162-027-10:Male/Female connector configuration, “F” type connector
162-028-10:Female/Female connector configuration, “F” type connector with integral ground block
Coax Protector
General Specifications
Part Number:162-029-10/162-027-10162-028-10
RF Performance:DC – 1GHz1GHz – 1.5GHz
Characteristic Impedance:75Ohms75Ohms
Insertion Loss (includes flatness):<0.1dB<0.2dB
Return Loss:>30dB>20dB
Protection
DC Breakdown @ 2000V/s:150V to 300V
Impulse Breakdown @ 100V/μs:<450V
Insulation Resistance:>100 MegOhms
Surge Life
10A, 10/1000μs:>1500 Surges
100A, 10/1000μs:>100 Surges
1000A, 10/1000μs:>10 Surges
5000A, 8/20μs:>10 Surges
AC Life
5A, 1000Vac, 1s:>5 Operations
1A, 1000Vac, 1s:>60 Operations
Failshort
30A, 1000Vac:>15min
Operating Temperature:-40 to 65°C / -40 to 149°F
Document Downloads
Title Type Version Date
Surge Protection Data Sheet Datasheet 049-226-10-008 June 10, 2011