Need Some Help?
|
Request a Quote
Home
Products
About Alpha
About Us
Careers
Contacts
Corporate Offices
Service Centers
Where to Buy
News Room
News Releases
Shows & Events
Newsletters
Training & Support
Toolkit
Catalogs
White Papers
Partners
Question / Answer
Select Your Country
Africa
Argentina
Armenia
Australia
Austria
Azerbaijan
Bahrain
Bangladesh
Belarus
Belgium
Bolivia
Brazil
Bulgaria
Burma
Canada
Caribbean
Central America
Chile
China
Colombia
Croatia
Cyprus
Czech Republic
Denmark
Eastern Europe
Ecuador
Egypt
Estonia
Finland
France
Georgia
Germany
Greece
Guam
Hong Kong
Hungary
India
Indonesia
Iran
Iraq
Ireland
Isle of Man
Israel
Italy
Japan
Jordan
Kazakhstan
Korea
Kuwait
Latvia
Lebanon
Lithuania
Luxembourg
Malaysia
Mexico
Netherlands
New Zealand
Norway
Oman
Pakistan
Palau
Paraguay
Peru
Philippines
Poland
Portugal
Puerto Rico
Qatar
Romania
Russia
Saudi Arabia
Serbia
Seychelles
Singapore
Slovak Republic
Slovenia
South Africa
Spain
Sweden
Switzerland
Taiwan
Thailand
Turkey
Turkmenistan
Ukraine
United Arab Emirates
United Kingdom
United States
Uruguay
Venezuela
Vietnam
Yemen
Products
Telecommunications
Products
Cordex Rectifiers
Cordex 3.1/3.6kW
Cordex 3.1/3.6kW
Cordex rectifiers feature some of the most innovative DC power technology today. Expert engineering combines the maximum in efficiency and reliability into one compact unit. The new Cordex series have power density improvements of 200-300% over previous rectifiers and incorporate many new features. Cordex rectifiers are available in a wide array of power sizes from 250 to 3600W per module, offering the most compact and cost effective power system design. Multiple DC output and AC input options are available to provide an ideal solution for most telecommunications and utility applications. Combining a unique blend of advanced features, high reliability and greater efficiency, Cordex rectifiers offer significant operational and capital savings. High power diversity modules provide users with greater rack space for additional revenue generating equipment in space-restricted environments. Fan cooled rectifier options are industry leading in terms of high temperature operation in harsh environments including outdoor enclosure solutions. Cordex rectifiers are designed to operate seamlessly with the Cordex CXC system controllers for advanced configuration and local or remote system control and monitoring.
Cordex 3.1/3.6kW
Electrical Specifications
>3.1kW Rectifier Module(s)
Part number
010-572-20
Input voltage
Nominal
208 to 277VAC
Operating
176 to 312VAC
Extended
176 to 90VAC (derated power)
Input frequency
45 to 70Hz
Power
3100W continuous/module
Power factor
>0.99 (50 to 100% load)
THD
<5%
Efficiency
>90%
Output voltage
21 to 29VDC
Output current
115A @ 27VDC (130A max. 24V)
Load regulation
<±0.5% (static)
Line regulation
<±0.1% (static)
Transient response
±2% for 50 to 100% load step,
2ms recovery time
Noise
Voice band
<32dBrnC
Wide band
<30mV RMS (10kHz to 10MHz)
<150mV pk to pk (10kHz to 100MHz)
Psophometric
<1.0mV
Acoustic
<60dBa @ 1m (3ft)
>3.6kW Rectifier Module(s)
Part number
010-567-20
Input voltage
Nominal
208 to 277VAC
Operating
176 to 312VAC
Extended
176 to 90VAC (derated power)
Input frequency
45 to 66Hz
Power
3600W continuous/module
Power factor
>0.99 (50 to 100% load)
THD
<5%
Efficiency
>92%
Output voltage
42 to 60VDC
Output current
66A @ 54VDC (75A max. 48V)
Load regulation
<±0.5% (static)
Line regulation
<±0.1% (static)
Transient response
±2% for 50 to 100% load step,
2ms recovery time
Noise
Voice band
<32dBrnC
Wide band
<30mV RMS (10kHz to 10MHz)
<150mV pk to pk (10kHz to 100MHz)
Psophometric
<1.0mV
Acoustic
<60dBa @ 1m (3ft)
Mechanical Specifications
Dimensions
mm
160H x 87W x 300D
inches
6.3H x 3.4W x 11.8D
Weight
4.6kg (10lb)
Features
Indicators
AC mains OK — green LED
Module OK — green LED
Module fail — red LED
Controls
CAN interface to CXC
Adjustments
Float voltage (via CXC controller)
Equalize voltage
High/low voltage alarm
High voltage shutdown
Current limit
Slope
Start delay
Protection
Current limit/short circuit
Start delay
Input/output fuses
Output high voltage shutdown
Power limiting
Thermal foldback/shutdown
Input transient
AC low line foldback shutdown
Environmental Specifications
Temperature
Standard
-40 to 65°C (-40 to 149°F)
Storage
-40 to 85°C (-40 to 185°F)
Humidity
0 to 95% RH non-condensing
Elevation
-500 to 4000m (-1640 to 13120ft)
Heat dissipation
<1176BTU per hour
Standards
Safety
CSA C22.2 No 60950-1-03
UL 60950-1 1st edition
CE marked
IEC/EN 60950-1
EMC
ETSI 300 386
Emissions
CFR47 (FCC) Part 15 Class B
ICES-03 Class B
EN55022 (CISPR 22) Class B
C-Tick (Australia)
EN 61000-3-2
EN 61000-3-3
Immunity
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
ANSI/IEEE C62.41 Cat B3
NEBS
GR-1089 CORE
GR-69 CORE
Document Downloads
Title
Type
Version
Date
Cordex 3.1kWr Datasheet - English (A4 Low Res.)
Datasheet
D03
June 1, 2006
Cordex 3.1kWr Datasheet - Spanish (A4 Low Res.)
Datasheet
D02
June 1, 2006
Cordex 3.6kWr Datasheet - Chinese (A4 Low Res.)
Datasheet
D02
June 1, 2006
Cordex 3.6kWr Datasheet - English (A4 Low Res.)
Datasheet
D03
June 1, 2006
Cordex 3.6kWr Datasheet - English (LTR Low Res.)
Datasheet
D08
May 1, 2007
Cordex 3.6kWr Datasheet - Russian (A4 Low Res.)
Datasheet
D01
June 1, 2006
Cordex 3.6kWr Datasheet - Spanish (A4 Low Res.)
Datasheet
D02
June 1, 2006
Total Power Solutions™
Home
Products
About Alpha
News Room
Training & Support
Careers
Feeds
Legal
Need Some Help?
Sitemap
Copyright © 2008, The Alpha Group. All Rights Reserved.