Cordex 1.8kW Modular Switched Mode Rectifier and Shelf
Cordex 1.8kW Modular Switched Mode Rectifier and Shelf
  • Available in 37.5A @ 48Vdc
  • High power density, fan cooled
  • Power limiting and wide range AC input
  • 91% efficiency and power factor correction
  • Bulk 48Vdc power systems up to 9kW


Cordex rectifiers bring advanced technology to the DC power industry. Innovative engineering combines the best in efficiency and reliability meeting the power requirements for a variety of system applications. With more than 9kW per 23" shelf, the fan cooled Cordex 1.8kW rectifier has extremely high density providing the most power in the least amount of space. A compact 2RU design accommodates five rectifiers per 23" shelf and four rectifiers per 19" shelf with integrated CXCI controller. An optional CXCM2 controller with touch screen display is available. Local and remote setup, adjustment, and control is a simple single-step process with the Cordex CXC System Controller. By utilizing TCP/IP technology, complete configuration and monitoring of power equipment is possible through a network web browser.
Cordex 1.8kW
Electrical Specifications
Input voltage
Nominal208 to 277Vac
Operating176 to 312Vac
Extended176 to 90Vac (derated power)
Input frequency45 to 66Hz
Power1800W continuous/module
Power factor>0.99 (50 to 100% load)
THD<5%
Efficiency>91%
Output voltage42 to 60Vdc
Output current33.3A @ 54Vdc (37.5A max. 48V)
Load regulation<±0.5% (static)
Line regulation<±0.1% (static)
Transient response±2% for 50 to 100% load step, 2ms recovery time
Noise
Voice band<32dBrnC
Wide band<30mV RMS (10kHz to 10MHz)
<150mV pk to pk (10kHz to 100MHz)
Psophometric<1mV
Acoustic<60dBa @ 1m (3ft)
Mechanical Specifications
Dimensions (in/mm)3.3 x 3.94 x 9.25 / 84 x 100 x 235
Weight (lb/kg)6.2 / 2.8
Features
IndicatorsAC mains OK — green LED
Module OK — green LED
Module fail — red LED
ControlsCAN interface to CXC Controller
Adjustments (via CXC Controller)Float voltage, Equalize voltage, High voltage alarm, Low voltage alarm, High voltage shutdown, Current limit, Slope, Start delay timers
ProtectionCurrent limit/short circuit, Start delay, Input/output fuses, Output high voltage shutdown, Power limiting, Thermal foldback/shutdown, Input transient, AC low line foldback/shutdown, AC high voltage shutdown
Environmental Specifications
Operating Temperature-40 to 65°C / -40 to 149°F
Storage Temperature-40 to 85°C / -40 to 185°F
Humidity0 to 95% non-condensing
Elevation-500 to 2800m / -1640 to 9186ft
Heat Dissipation<608BTU per hour
Standards
SafetyCSA C22.2 No 60950-1-03
UL 60950-1 1st Edition
CE marked
IEC/EN 60950-1
EMCETSI 300 386
EmissionsCFR47 (FCC) Part 15 Class B
ICES-03 Class B
EN55022 (CISPR 22) Class B
C-tick (Australia)
EN 61000-3-2
EN 61000-3-3
ImmunityEN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
ANSI/IEEE C62.41 Cat B3
19" and 23" Shelf Systems
Mechanical Specifications
Dimensions (in/mm)3.5 x 17.2 x 12.2 / 89 x 438 x 310
Mounting19" flush or center mount, 23" center mount only
Weight (lb/kg)19 / 8.5
23" Shelf Systems
Mechanical Specifications
Dimensions (in/mm)3.5 x 21.3 x 12.2 / 89 x 541 x 310
Mounting23" flush or center mount
Weight (lb/kg)22 / 10
Connections
InputTerminal Block. Mini-fit connectors (23" only)
OutputBus adapters with 3/8" on 1" centers
Chassis Ground1/4" studs on 5/8" centers
CAN CommunicationRJ12 offset
Document Downloads
Title Type Version Date
Cordex 1.8kWr Datasheet - Chinese (A4 Low Res.) Datasheet D01 June 1, 2006
Cordex 1.8kWr Datasheet - English (A4 Low Res.) Datasheet D02 June 1, 2006
Cordex 1.8kWr Datasheet - English (LTR Low Res.) Datasheet D04 May 1, 2007