Alpha Technologies Inc.
Phone: 360 647 2360
Email: alpha@alpha.com
AlphaNet EDH2
  • Supports multiple power supply models, multiple battery strings and a generator
  • Compatible with ANSI/SCTE HMS standards
  • Optional VoIP testing features


Alpha’s External DOCSIS Transponder provides the ability for cable operators to manage any network UPS through the existing cable modem infrastructure. Alpha’s EDH2 transponder supports monitoring multiple power supply models including XM2, XM, AM, ZTT/Plus and CPR. The power supply, multiple batteries and a generator can be monitored using a single transponder. Power supply status is transmitted to a management system over the network’s DOCSIS cable modem channels through the existing CMTS. Bandwidth use is minimized by using standard SNMP (Simple Network Management Protocol) communications. Status monitoring information is compatible with ANSI/SCTE HMS standards. Optional VoIP testing functionality allows power supply transponder to become a powerful network diagnostic tool.
Specifications
General
Power Supplies SupportedXM2 (requires USM2 or USM2.5 card)
XM (requires USM) AM (requires RPM card)
Lectro ZTT, ZTT+ and CPR
DOCSIS CompatibilityFirmware DOCSIS 1.1
Monitoring ProtocolSNMPv1
Devices MonitoredPower Supply, Batteries and Generator (analog status approximates ANSI/SCTE 25-3 2002, formerly HMS 022)
RF Transmit/Receive
Tx Frequency Range5 to 42MHz
Output Power8 to 58dBmV
Channel Bandwidth6MHz
Receive Center Freq Range91 to 857MHz (Standard, HRC, IRC channels)
Input Level-15 to 15dBmV
Monitored Parameters
Number of Battery StringOne to Four of 36V or 48V
Battery DataIndividual Battery Voltages
Battery Compartment Temperature
Generator Data(Requires AlphaGen generator system with ECM status interface)
• Major Alarms (Consists of Low Oil Pressure, Engine Over-temp, Engine Over-speed, Crank Limit, Over Voltage, Low Fuel, Water Intrusion, Pad Shear, Gas Hazard, Test Fail)
• Minor Alarm (Consists of Control Fail, Alternator Fail, Low Ignition Battery Voltage, Manual Bypass Active, Enclosure Door, DC Voltage Tolerance, Engine Disabled, Service Required)
• Engine Alarm (Consists of Low Oil Pressure, Engine Over-temp, Engine Over-speed, Crank Limit, Engine Disabled)
• Gas Hazard
• Enclosure Alarm
• Test Status
• Enclosure Door
• Remote Test Control
Hardware
RF Cable InterfaceF-connector, female, 75 0hm
Local InterfaceRJ-12, RS-232, 19.2kb,N,8,1
Requires serial port adapter and PC with terminal emulation software (Hyper-Terminal recommended)
LED IndicatorsRF Transmit, RF Receive/Link, Transponder Ready, Local Data
Environmental-40° to 65°C / -40° to 149° F, 10 to 90% non-condensing humidity
EmissionsEN55022 Class A and FCC Part 15 Class A (Installed in power supply enclosure system)
Warranty2 years
Dimensions (in/mm)4.6D x 5.75W x 1.5H / 116.8D x 146.1W x 38.1H
Management
NMS/EMS• Cheetah™ DOCSIS® Management Software
• Standard SNMP Management Tools
HMS MIBsPower Supply (ANSI/SCTE 38-4)
Generator (ANSI/SCTE 38-6)
Transponder (ANSI/SCTE 38-3)
Alarm/Trap (ANSI/SCTE 38-1 and 38-2)
Ordering Information
XP-EDH2External DOCSIS Transponder for XM2, XM, AM, Lectro ZTT compatible with VoIP Test Function (745-419-20). Order power supply interface cables and battery sense kit separately.
XMZ-ICKInterface cable for monitoring XM2 with USM2 or USM2.5 status interface (875-335-20)
XM/AM-ICKInterface cable for monitoring XM with USM and AM with RPM status interface (875-335-21)
RPM factory configured for AM Communications
ZTT-ICKInterface cable for monitoring ZTT or ZTT+ (875-335-22)
ZTT-ICKZInterface cable for monitoring ZTT+ (875-335-23)(pre 1998 versions)
DCO-ADPTRLocal port adaptor (875-349-10)
Battery Sense Wire Kits
XP-BSC-24-2-61x24V, 6ft / 875-401-20
XP-BSC-24-2-62x24V, 6ft / 875-401-21
XP-BSC-24-2-91x24V, 9ft / 875-401-22
XP-BSC-24-4-92x24V, 9ft / 875-401-23
XP-BSC-3-61x36V, 6ft / 874-842-21
XP-BSC-3-91x36V, 9ft / 874-842-27
XP-BSC-6-92x36V, 9ft / 874-842-28
XP-BSC-4-61x48V, 6ft / 874-841-21
XP-BSC-8-62x48V, 6ft / 874-841-20
XP-BSC-4-91x48V, 9ft / 874-841-24
XP-BSC-8-92x48V, 9ft / 874-841-25
Document Downloads
Title Type Version Date
AlphaNet External Data Sheet - English (A4) Datasheet 049-233-15-002 February 1, 2006
AlphaNet External Data Sheet - English (LTR) Datasheet 049-233-11-004 February 1, 2006