Alpha Technologies Inc.
Phone: 360 647 2360
Email: alpha@alpha.com
AlphaCell GXL
AlphaCell GXL GelCell Batteries
    NEW 195 GXL and 220 GXL:
  • High-performance Silver Alloy for maximum life expectancy
  • Longer runtime for demanding outdoor environments
  • 100% runtime capacity out-of-box – No cycling required
  • Maintenance-free threaded inserts — No periodic retorquing
  • Available with 4 and 5 year full warranties
  • Wide operating temperature range


Alpha’s standby battery offering incorporates Gel for thermal dissipation to ensure optimal life performance for your particular Broadband, Traffi c or Wi-fi application. AlphaCell Batteries provide the longest runtimes and the best longevity in today’s demanding outdoor applications and are backed by Alpha’s industryleading, non-prorated hassle-free warranties.

Monitor and protect AlphaCell batteries with AlphaGuard™ Battery Charge Management System.
AlphaCell GXL GelCell Batteries
General Specifications
Model:220 GXL195 GXL165 GXL
Warranty:4 to 6 years4 to 6 years4 to 5 years
Service Life:ExtendedExtendedExtended
Runtime (minutes):221196165
VRLA Battery Type:Gel Silver Alloy
Heat Resistant:ExtremeExtremeExtreme
Hydrogen Emission:LowLowLow
Terminals:Threaded insert 1/4” - 20 UNC
Cells Per Unit:666
Voltage Per Unit:12.812.812.8
Conductance Value:117511001000
Max. Discharge Current (A):900900800
Short Circuit Current (A):280026002500
10 Second Volts @ 100A:11.411.311.2
Ohms Impedance 60Hz:0.00500.00500.0055
Capacity at 20hrs (to 1.75VPC):109AH100AH86AH
BCI Group Size:313127
Weight (lb/kg):73/33.267/30.563/28.6
Dimensions H x W x D (in/mm):8.5 x 13.4 x 6.8 / 215 x 341 x 1738.5 x 13.4 x 6.8 / 215 x 341 x 1738.1 x 12.5 x 6.8 / 205 x 318 x 173
Operating Temperature Range
Discharge:-40 to 71°C (-40 to 160°F)-40 to 71°C (-40 to 160°F)-40 to 71°C (-40 to 160°F)
Charge (with temp compensation):-23 to 60°C (-9.4 to 140°F)-23 to 60°C (-9.4 to 140°F)-23 to 60°C (-9.4 to 140°F)
Float Charging Voltage (Vdc):13.5 to 13.813.5 to 13.813.5 to 13.8
AC Ripple Charger:0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% pk to pk
Document Downloads
Title Type Version Date
Battery Recycling Information Sheet Datasheet 049-018-78-001 June 1, 2010
AlphaCell Gold and GXL MSDS - ENG Advisory 049-018-29-004 July 28, 2009
AlphaCell GXL GelCell Datasheet_Eng Datasheet 049-297-10-C003 October 14, 2009
AlphaCell MSDS Sheet - Spanish Advisory 2009 August 1, 2009
Connecting Battery Cable kits to Threaded Insert Terminals on AlphaCell Batteries Advisory 875-607-C0-001 Rev. A January 1, 2007
AlphaCell Gel Cell Battery Users' Guide (Storage, Maintenance and Deployment) Manual 745-680-C0-002 Rev. B October 16, 2009


You might also be interested in these other Alpha products:
AlphaGuard™
Battery Charge Management
Battery Heater Mats
For Cold Weather Apps
Celltron Essential
Test for 6/12V Batteries