Need Some Help?
|
Request a Quote
Home
Products
About Alpha
About Us
Careers
Contacts
Corporate Offices
Service Centers
Where to Buy
News Room
News Releases
Shows & Events
Newsletters
Training & Support
Toolkit
Catalogs
White Papers
Partners
Question / Answer
Select Your Country
Africa
Argentina
Armenia
Australia
Austria
Azerbaijan
Bahrain
Bangladesh
Belarus
Belgium
Bolivia
Brazil
Bulgaria
Burma
Canada
Caribbean
Central America
Chile
China
Colombia
Croatia
Cyprus
Czech Republic
Denmark
Eastern Europe
Ecuador
Egypt
Estonia
Finland
France
Georgia
Germany
Greece
Guam
Hong Kong
Hungary
India
Indonesia
Iran
Iraq
Ireland
Isle of Man
Israel
Italy
Japan
Jordan
Kazakhstan
Korea
Kuwait
Latvia
Lebanon
Lithuania
Luxembourg
Malaysia
Mexico
Netherlands
New Zealand
Norway
Oman
Pakistan
Palau
Paraguay
Peru
Philippines
Poland
Portugal
Puerto Rico
Qatar
Romania
Russia
Saudi Arabia
Serbia
Seychelles
Singapore
Slovak Republic
Slovenia
South Africa
Spain
Sweden
Switzerland
Taiwan
Thailand
Turkey
Turkmenistan
Ukraine
United Arab Emirates
United Kingdom
United States
Uruguay
Venezuela
Vietnam
Yemen
Products
Renewable Energy
Off-Grid Solar Systems
12V SPS
12V Solar Power Systems
Cost-effective alternative to AC line extension
Reliable power where you need it, when you need it
Minimum of six days of design load autonomy
Engineered for pole or pad mounting, and rapid field deployment
Applications include: Security systems, traffic systems, emergency power, cathodic protection, navigational aids, WiMax and SCADA.
Solar Power Systems (SPS) can be configured to provide a range of DC or AC power outputs. Systems include the most recent advances in PV manufacturing, electronic controls and power management. Standard controls include temperature-compensated 3-stage battery charging, battery low voltage disconnect, lightning protection and complete circuit protection. Each system comes with a two-year limited warranty (extended warranties are available), while the PV modules carry a 20 to 25-year performance guarantee.
The SPS design incorporates a minimum of six days load autonomy, providing reliable power with no operational or maintenance costs and near-zero annual load loss probability. Systems are engineered for pole or pad mounting and packaged for easy installation.
Options Include: Multiple output breakers, data logging of system operating parameters, alarm outputs for critical system parameters, DC to AC inverter for AC loads and additional enclosure for customer use.
New York State Case Study
Hazardous Waste Site
Solar Power Systems
Specifications
SPS12-85/108G
SPS12-110/170G
SPS12-255/324G
Electrical Specifications, Solar Panel
Maximum Power
85W
55W
85W
Power Tolerance
+-5%
+-5%
+-5%
Maximum Power Voltage
17.5Vdc
17.3Vdc
17.5Vdc
Maximum Power Current
4.86A
3.18A
4.86A
Open Circuit Voltage
22.0Vdc
21.7Vdc
22.0Vdc
Open Circuit Current
5.36A
3.47A
5.36A
Maximum System Voltage
600Vdc
600Vdc
600Vdc
Nominal Operating Cell Temperature
47° C, +-2° C
47° C, +-2° C
47° C, +-2° C
Operating Temperature
-40° C to +90° C
-40° C to +90° C
-40° C to +90° C
Dielectric Isolation Voltage
1000Vdc
1000Vdc
1000Vdc
Maximum Wind Resistance
60m/s
60m/s
60m/s
Maximum Hail Diameter @ 80km/h
25mm
25mm
25mm
Mechanical Specifications, Solar Panel:
Length(in/mm)
46.29/1176
39.84/1012
43.29/1176
Width(in/mm)
20.78/528
17.51/445
20.78/528
Depth(in/mm)
1.25/32
1.25/32
1.25/32
Weight(kg/lb.)
7.5/16.5
6/13.2
7.5/16.5
Frame
Aluminum
Aluminum
Aluminum
Front Side
Glass, 3.2mm
Glass, 3.2mm
Glass, 3.2mm
Encapsulant
EVA
EVA
EVA
Cell Type
Single Crystal Cell
Single Crystal Cell
Single Crystal Cell
Number Cells
36 in Series
36 in Series
36 in Series
General Specifications, Rack
Angle
15 to 60° from Horizontal
15 to 60° from Horizontal
0 to 90°
Pole
Customer Supplied 2.5” Schedule 40 or 80
Customer Supplied 2.5” Schedule 40 or 80
Customer Supplied 3” Schedule 40 or 80
Electrical Specifications, Solar Controller
Rated Solar Input
10A
10A
20A
Rated Load
10A
10A
20A
Current Overload
25% for 5 minutes
25% for 5 minutes
25% for 5 minutes
Regulated Output Voltage
14.1Vdc
14.1Vdc
14.1Vdc
Load Disconnect
11.5Vdc
11.5Vdc
11.5Vdc
LVD Reconnect
12.6Vdc
11.5Vdc
11.5Vdc
Temperature Compensation
-28 mV/° C
-28 mV/° C
-28 mV/° C
Self-Consumption
6 to 10mA
6 to 10mA
6 to 10mA
Operating Temperature
-40 to +85° C
-40 to +85° C
-40 to +85° C
Battery Charger
True 0 to 100% PWM duty cycle
True 0 to 100% PWM duty cycle
True 0 to 100% PWM duty cycle
Setpoint accuracy
< 35mV
< 35mV
< 35mV
General Specifications, Battery
Voltage
12V (nominal)
12V (nominal)
12V (nominal)
Capacity
108 Ah at the 100 hour rate, to 1.75 VPC at 27° C (80° F)
170 Ah at the 100 hour rate, to 1.75 VPC at 27° C (80° F)
255 Ah at the 100 hour rate, to 1.75 VPC at 27° C (80° F)
Type
Gel
Gel
Gel
Plate Alloy
Lead Calcium
Lead Calcium
Lead Calcium
Element, Post
3/8” x 16 Stainless Steel Stud Posts
Offset post with Horizontal Hole, Stainless
3/8” x 16 Stainless Steel Stud Posts
Mechanical Specifications, Integrated Control/Battery Enclosure
Size
24x25x14
24x25x14
24x25x15
Weight (lb.)
109
144
270
Features
Minimum of six days of design load autonomy
No routine operational and maintenance costs
Engineered for pole or pad mounting, and rapid field deployment
Rugged aluminum control/battery enclosure
Cost-effective alternative to AC line extension
Reliable power where you need it, when you need it!
Options
Output voltage regulation
Multiple output breakers
Data logging of system operating parameters
Alarm outputs for critical system parameters
DC to AC inverter for AC loads
Additional enclosure for customer use
Document Downloads
Title
Type
Version
Date
SPS New York State Case Study
Datasheet
49-238-15-001
July 1, 2006
SPS Systems Data Sheet_Eng
Datasheet
049-238-13-003
February 1, 2008
Total Power Solutions™